Símbolo Fondo Science

Contacte para más información en el teléfono +34 629 829 605

Revista Española de Artroscopia y Cirugía Articular

Asociación Española de Artroscopia (AEA)

ISSN online: 2443-9754 (es)
ISSN impreso: 2386-3129 (es)
Vol. 17. Fasc. 1. Núm. 41. Abril 2010
DOI: (sin asignar)
Recibido: Abril 2010
Aceptado: Abril 2010
Originales

Nuevo abordaje artroscópico de la cirugía de cadera: técnica out-inside

A new arthroscopic approach for hip surgery: out-inside technique

Cuad Artroscop. 2010;17(1):27-35

Resumen: 

Introducción: el tratamiento del CFA ha sido un impulso para que la artroscopia de cadera se convierta en una opción válida. No obstante, el estado actual del arte presenta una disuasoria complejidad técnica.

Objetivo: se propone abordar la técnica artroscópica, reproduciendo el acceso de la cirugía abierta.

Material y método: se realizan 28 artroscopias de cadera consecutivamente. Se realiza un acceso pericapsular, una capsulotomía y posteriormente el tratamiento de las lesiones tanto en el lado pélvico como en el femoral. Se miden los tiempos parciales de tracción, el uso de fluoroscopia y la duración total de la intervención.

Resultados: el tiempo medio de tracción fue de 19,02 minutos; el de fluoroscopia, de 2 minutos; y el de la duración de la cirugía, de 93,5 minutos.

Discusión: se propone un abordaje del tratamiento más sencillo desde el punto de vista técnico. Se utiliza preferentemente visión con óptica de 30º, instrumentación artroscópica no específica de esta articulación y menos tiempo de tracción.

Abstract: 

Background: the therapeutic management of CFA has pushed hip arthroscopy to the status of a valid option. However, the current state of the art evidences a dissuading technical complexity.

Aim: we propose an approach to the arthroscopic technique reproducing the open-surgery one.

Material and methods: 28 consecutive hip arthroscopies were performed. A pericapsular approach was used, with capsulotomy and then correction of the lesions both in the pelvic and in the femoral aspects. The partial traction, fluoroscopy use and total surgery times were measured.

Results: the mean traction time was 19.02 minutes; the mean fluoroscopy time, 2 minutes; and the mean total surgery, duration 93.5 minutes.

Discussion: a new therapeutic approach is proposed that is technically easier to perform. It uses preferently a 30º optic system and arthroscopic instrumentation that is not specific for this joint, and the traction time is less.

Cita bibliográfica

Margalet Romero E, Mediavilla I, Marín Peña ONuevo abordaje artroscópico de la cirugía de cadera: técnica out-inside. Cuad Artroscop. 2010;17(1):27-35. doi: DOI: (sin asignar)

Descargar artículo: 

Icono PDF fs_17141.fs1004005-nuevo-abordaje-artroscopico.pdf

Licencia: 

Este contenido es de acceso abierto (Open-Access) y se ha distribuido bajo los términos de la licencia Creative Commons CC BY-NC-ND (Reconocimiento-NoComercial-SinObraDerivada 4.0 Internacional) que permite usar, distribuir y reproducir en cualquier medio siempre que se citen a los autores y no se utilice para fines comerciales ni para hacer obras derivadas.